Esplora le Attrezzature Zootecniche di Qualità

Art. FDA-000024TP – 1/2″ automatic nipple drinker for pig feeders (wet/dry)

1/2” threaded connection for wet/dry pig feeders, with brass body and stainless steel pin. Adjustable plastic filter. Automatic activation by the pig’s head for controlled feed wetting. Also available in full stainless steel version.

👉 (CLICK HERE) for the complete installation table

👉 (CLICK HERE) for the flow rate table

👉 (CLICK HERE) for the technical drawing

Art. FDA-000024TP - 1/2" automatic nipple drinker for pig feeders (wet/dry)

Product description

The FDA-000024TP automatic nipple drinker is designed for use inside feeders (wet/dry systems), ensuring a constant water supply directly during feed intake.

This solution improves feed intake, promotes animal hydration, and reduces waste, keeping the rearing area cleaner.

Made with robust and wear-resistant materials, it is ideal for pig farms requiring reliability, durability, and ease of management.


Technical specifications

  • Brass thread

  • Stainless steel tube and pin

  • 1/2" water connection

  • Total length: 95.5 mm

  • Drinker tube Ø 21 mm

  • Pin Ø 8 mm

  • Weight: 82.9 g

  • 21 mm hexagon

  • Valve with adjustable plastic filter


Installation heights and angle

👉 (CLICK HERE) for the complete installation table

The indicated heights are general guidelines.

The FDA-000024TP drinker is designed to be installed inside feeders, so that the pig can activate it while eating.

For piglet rearing, we recommend using two installation heights or height adjusters to adapt the position to the animals' growth.

The inclination can be adjusted between 30° and 45°:

  • Piglets (7–20 kg)

    • Height: 8–12 cm above feeder bottom
    • Angle: 30°–45°
    • Pressure: 0.5–1.5 bar
    • Flow rate: 0.5–0.8 L/min

    Weaners / Growers (20–40 kg)

    • Height: 12–18 cm
    • Angle: 35°–45°
    • Pressure: 1–2 bar
    • Flow rate: 0.7–1.0 L/min

    Finishers (40–80 kg)

    • Height: 18–25 cm
    • Angle: 40°–45°
    • Pressure: 1–2.5 bar
    • Flow rate: 0.8–1.2 L/min

    Fattening (80–120+ kg)

    • Height: 25–35 cm
    • Angle: 45°
    • Pressure: 1.5–3 bar
    • Flow rate: 1.0–1.5 L/min

Correct installation allows the water flow to be directed straight into the feed, reducing waste and improving feed efficiency.


Recommended water pressure

All drinkers work at both low and high pressure, with a maximum value of 4 bar (55 psi).

For piglet rearing, water pressure should not exceed 2 bar (28 psi).

In general, lower pressures promote:

  • water savings

  • less wear on seals and spring

  • gentler water flow

  • greater ease of use

  • waste reduction

👉 We recommend using a pressure reducer in the presence of high or variable values.


Water flow rate

👉 (CLICK HERE) for the flow rate table

The flow rate of the 1/2" automatic nipple drinker varies according to the pressure in the water line.

For optimal system operation, a flow rate between 0.7 and 1.5 L/min is recommended to achieve correct feed moistening, reducing water waste and keeping the feeding area cleaner.

In the version with adjustable valve (model FDA-000024TP), the flow rate can be set via the valve cap, allowing the flow to be adapted to the pressure available in the system.

The graph highlights three adjustment levels:

  • Level 1 (2–9 bar) – green zone
    for high-pressure systems

  • Level 2 (1–2 bar) – blue zone
    for intermediate pressures

  • Level 3 (0–1 bar) – grey zone
    for low-pressure lines

The graph allows you to quickly identify the correct level to set on the cap to obtain a stable flow rate based on the available pressure.

With correct adjustment, the flow rate remains around 1.0 L/min, ensuring a constant, reliable flow suitable for different farming conditions.

The use of pressure reducers allows for centralized flow management, particularly useful during hot periods.


Water contamination

Water or pipe contamination is one of the main causes of drinker malfunction.

The presence of impurities or sediment can compromise the correct operation of the system and reduce its lifespan.

👉 We recommend installing a filter on the water system to prevent these issues and ensure consistent performance.